Key Features

  • Package Contains: Two (2) dual run capacitors
  • Capacitance Rating: 70 + 7.5 Microfarad (MFD)
  • Capacitance Tolerance: +/- 5%
  • Voltage Rating: 370 or 440 Volts AC (VAC)
  • Frequency: 50 / 60 Hz
  • Shape: Round
  • Terminals: 3 (Common, Fan, Hermetic Compressor)
  • Construction: Oil-filled, metal case
  • Operating Temperature Range: -40°C to +70°C
  • Meets EIA-456-A industry standards

Replaces / Cross-Reference Part Numbers

  • USA2222A
  • Jard 12954
  • P291-7074R
  • C37075R
  • C47075R
  • PRCFD707.5A
  • Replaces any round dual run capacitor with matching 70/7.5 MFD and 370V or 440V specifications.

Compatibility & Fitment

  • Designed for HVAC applications including air conditioners, heat pumps, and condenser units.
  • Functions as a direct replacement for capacitors with identical capacitance (MFD) and voltage ratings.
  • A 440V rated capacitor can safely replace a 370V capacitor; do not replace a 440V capacitor with a 370V unit.
  • Verify physical dimensions (diameter and height) to ensure proper fit in the mounting bracket.

When to Replace

  • AC unit or fan motor will not start or is slow to start.
  • A humming noise comes from the unit during attempted startup.
  • The capacitor case is visibly swollen, bulging, or leaking oil.
  • The compressor starts, but the condenser fan does not spin.

Installation Tips

  • Disconnect all electrical power to the HVAC unit before beginning work.
  • Carefully discharge the old capacitor by shorting the terminals with an insulated screwdriver.
  • Note or photograph the wire placement on the C (Common), FAN, and HERM (Hermetic) terminals before disconnecting.
  • Connect wires to the corresponding terminals on the new capacitor.
  • Securely mount the new capacitor in the unit's bracket.
  • Professional installation is recommended if you are not familiar with HVAC electrical systems.

Compatibility & Fitment

    $39.24
    [Lifetime Warranty] 70+7.5 uF MFD 370/440 VAC Round Dual Run Capacitor - Compatible with Air Conditioner, Heat Pump Condenser - Pack of 2
    $39.24

    Product Information

    Shipping & Returns

    Description

    70+7.5 MFD uf 370 or 440 Volt VAC Round Dual Run Capacitor - Pack of 2

    Key Features

    • Package Contains: Two (2) dual run capacitors
    • Capacitance Rating: 70 + 7.5 Microfarad (MFD)
    • Capacitance Tolerance: +/- 5%
    • Voltage Rating: 370 or 440 Volts AC (VAC)
    • Frequency: 50 / 60 Hz
    • Shape: Round
    • Terminals: 3 (Common, Fan, Hermetic Compressor)
    • Construction: Oil-filled, metal case
    • Operating Temperature Range: -40°C to +70°C
    • Meets EIA-456-A industry standards

    Replaces / Cross-Reference Part Numbers

    • USA2222A
    • Jard 12954
    • P291-7074R
    • C37075R
    • C47075R
    • PRCFD707.5A
    • Replaces any round dual run capacitor with matching 70/7.5 MFD and 370V or 440V specifications.

    Compatibility & Fitment

    • Designed for HVAC applications including air conditioners, heat pumps, and condenser units.
    • Functions as a direct replacement for capacitors with identical capacitance (MFD) and voltage ratings.
    • A 440V rated capacitor can safely replace a 370V capacitor; do not replace a 440V capacitor with a 370V unit.
    • Verify physical dimensions (diameter and height) to ensure proper fit in the mounting bracket.

    When to Replace

    • AC unit or fan motor will not start or is slow to start.
    • A humming noise comes from the unit during attempted startup.
    • The capacitor case is visibly swollen, bulging, or leaking oil.
    • The compressor starts, but the condenser fan does not spin.

    Installation Tips

    • Disconnect all electrical power to the HVAC unit before beginning work.
    • Carefully discharge the old capacitor by shorting the terminals with an insulated screwdriver.
    • Note or photograph the wire placement on the C (Common), FAN, and HERM (Hermetic) terminals before disconnecting.
    • Connect wires to the corresponding terminals on the new capacitor.
    • Securely mount the new capacitor in the unit's bracket.