Key Features

  • Capacitance: 25 MFD / uF
  • Tolerance: ± 5%
  • Voltage Rating: 370V or 440V AC
  • Frequency: 50/60 Hz
  • Shape: Round
  • Dielectric Fluid: Non-PCB Oil
  • Case Material: Aluminum
  • Terminals: 1/4 inch male spade terminals
  • Safety Standard: UL Recognized

Replaces / Cross-Reference Part Numbers

  • Replaces any single-value, round motor run capacitor with matching 25 MFD and 370V or 440V specifications.
  • A 440V rated capacitor can be used as a direct replacement for a 370V rated capacitor with the same MFD value.
  • Compatible replacement for capacitors from brands including Genteq, MARS, Packard, and Aerovox.

Compatibility & Fitment

  • Designed for continuous duty in single-phase motor applications.
  • Commonly used in HVAC systems, including air conditioner condenser units and heat pumps.
  • Suitable for compressor motors and fan motors.
  • Also used in pool pumps, refrigerators, furnaces, and other motor-driven equipment.

When to Replace

  • Motor hums but fails to start or operates intermittently.
  • Fan motor runs slower than normal or requires a manual push to start.
  • Compressor does not start, preventing the system from cooling.
  • Visible damage to the old capacitor, such as a bulging top, cracks, or fluid leakage.
  • Capacitance measures outside the rated 25 MFD ± 5% range when tested with a multimeter.

Installation Tips

  • Warning: Disconnect all electrical power to the unit before handling or replacing the capacitor.
  • Capacitors can hold a dangerous electrical charge. Safely discharge the old capacitor by shorting across the terminals with an insulated tool.
  • Before installing, verify the MFD and voltage ratings of the new capacitor match the requirements of your equipment.
  • Note the wire placement on the old capacitor's terminals before disconnecting.
  • Ensure the new capacitor is securely mounted and all wire connections are tight.
$23.54
[Lifetime Warranty] 25 uF MFD ±5% 370/440 VAC Multi-Purpose Motor Run Round Capacitor - Compatible with Air Conditioner, Heat Pump
$23.54

Product Information

Shipping & Returns

Description

25 MFD uf ± 5% MFD 370 V VAC or 440 Volt Multi-Purpose Motor Run Round Capacitor

Key Features

  • Capacitance: 25 MFD / uF
  • Tolerance: ± 5%
  • Voltage Rating: 370V or 440V AC
  • Frequency: 50/60 Hz
  • Shape: Round
  • Dielectric Fluid: Non-PCB Oil
  • Case Material: Aluminum
  • Terminals: 1/4 inch male spade terminals
  • Safety Standard: UL Recognized

Replaces / Cross-Reference Part Numbers

  • Replaces any single-value, round motor run capacitor with matching 25 MFD and 370V or 440V specifications.
  • A 440V rated capacitor can be used as a direct replacement for a 370V rated capacitor with the same MFD value.
  • Compatible replacement for capacitors from brands including Genteq, MARS, Packard, and Aerovox.

Compatibility & Fitment

  • Designed for continuous duty in single-phase motor applications.
  • Commonly used in HVAC systems, including air conditioner condenser units and heat pumps.
  • Suitable for compressor motors and fan motors.
  • Also used in pool pumps, refrigerators, furnaces, and other motor-driven equipment.

When to Replace

  • Motor hums but fails to start or operates intermittently.
  • Fan motor runs slower than normal or requires a manual push to start.
  • Compressor does not start, preventing the system from cooling.
  • Visible damage to the old capacitor, such as a bulging top, cracks, or fluid leakage.
  • Capacitance measures outside the rated 25 MFD ± 5% range when tested with a multimeter.

Installation Tips

  • Warning: Disconnect all electrical power to the unit before handling or replacing the capacitor.
  • Capacitors can hold a dangerous electrical charge. Safely discharge the old capacitor by shorting across the terminals with an insulated tool.
  • Before installing, verify the MFD and voltage ratings of the new capacitor match the requirements of your equipment.
  • Note the wire placement on the old capacitor's terminals before disconnecting.
  • Ensure the new capacitor is securely mounted and all wire connections are tight.
[Lifetime Warranty] 25 uF MFD ±5% 370/440 VAC Multi-Purpose Motor Run Round Capacitor - Compatible with Air Conditioner, Heat Pump | BlueStars Quality Replacement Parts